DC-01 ↔ DC-02
Selected group’s optics, connection layout and channel checks.
100GBASE-SR4
QSFP-100G-SR4-S
4 × 25G NRZ parallel · 850 nm
Automatic selection considers reach, verified loss budget and shortest adequate reach; it is not a price ranking.
FEC: Verify the exact SKU and host mode
End-to-end connection
One route shown · Click for detailsEndpoint patch cords: A 48 × 3 m + B 48 × 3 m. Panels and backbone include 25% growth.
Reach check
Worst fiber path • loss
Alternatives at the same speed
Reach + loss assessment| Optical profile | Fiber | Reach | Active fibers | Check | |
|---|---|---|---|---|---|
| 100GBASE-SR4QSFP28 · MPO-12 UPC | OM4 | 100 m | 8 | Reach + loss pass | |
| 100GBASE-SR4QSFP28 · MPO-12 UPC | OM5 | 100 m | 8 | Reach + loss pass | |
| 100GBASE-DRQSFP28 · LC duplex UPC | OS2 | 500 m | 2 | Reach + loss pass | |
| 100G CWDM4 MSAQSFP28 · LC duplex UPC | OS2 | 2 km | 2 | Reach + loss pass | |
| 100GBASE-LR4QSFP28 · LC duplex UPC | OS2 | 10 km | 2 | Reach + loss pass | |
| 100GBASE-SR1QSFP28 · LC duplex UPC | OM4 | 100 m | 2 | Reach passes · budget unknown | |
| 100GBASE-SR1QSFP28 · LC duplex UPC | OM5 | 100 m | 2 | Reach passes · budget unknown | |
| 100G PSM4 MSAQSFP28 · MPO-12 APC | OS2 | 500 m | 8 | Reach passes · budget unknown | |
| 100GBASE-FR1QSFP28 · LC duplex UPC | OS2 | 2 km | 2 | Reach passes · budget unknown | |
| 100GBASE-LR1QSFP28 · LC duplex UPC | OS2 | 10 km | 2 | Reach passes · budget unknown | |
| 100G ER4-LiteQSFP28 · LC duplex UPC | OS2 | 40 km | 2 | Engineering checks required | |
| 100G ZR4 80 km (vendor profile)QSFP28 · LC duplex UPC | OS2 | 80 km | 2 | Engineering checks required | |
| 100GBASE-SR4QSFP28 · MPO-12 UPC | OM3 | 70 m | 8 | Reach outside limits | |
| 100GBASE-SR1QSFP28 · LC duplex UPC | OM3 | 70 m | 2 | Reach outside limits |
Manufacturer datasheet ↗ · Verify exact part number, FEC, port mode and software support in the host compatibility matrix.
Patch panels & fiber infrastructure
This section shows one route of the selected group. Each endpoint is sized separately.
Fiber & termination quantities
One route · Both endsRoute & cable tray
One independent route · Geometric preplanningProject bill of materials
All groups and independent routes. Installed quantities and inventory spares are separate.
| Item / specification | Unit | Install | Stock spare | Purchase |
|---|---|---|---|---|
| 1. DC-01 ↔ DC-02 · 100G · 1 route(s) | ||||
| Optical module • End AQSFP-100G-SR4-S · 100GBASE-SR4 | pcs | 48 | 5 | 53 |
| Optical module • End BQSFP-100G-SR4-S · 100GBASE-SR4 | pcs | 48 | 5 | 53 |
| Unloaded panel chassis • End A1U · 12 MPO | pcs | 5 | 0 | 5 |
| Unloaded panel chassis • End B1U · 12 MPO | pcs | 5 | 0 | 5 |
| Panel adapters • End AMPO-12 UPC | pcs | 60 | 0 | 60 |
| Panel adapters • End BMPO-12 UPC | pcs | 60 | 0 | 60 |
| Device patch cord • End AOM4 · MPO-12 UPC ↔ MPO-12 UPC · 3 m | pcs | 48 | 5 | 53 |
| Device patch cord • End BOM4 · MPO-12 UPC · 3 m | pcs | 48 | 5 | 53 |
| Backbone fiber cable12F OM4 · 66 m / cable · MPO-12 UPC | pcs | 60 | 0 | 60 |
| 1U horizontal cable managerBoth endpoints combined | pcs | 10 | 0 | 10 |
Infrastructure by group
| Group | Links | Optics + spares | Panels | Passive space | Backbone cable length |
|---|---|---|---|---|---|
| DC-01 ↔ DC-02 | 48 | 96 + 10 | 10 | 20U | 3.96 km |
Optics & fiber catalog
1G–1.6T Ethernet • 43 vendor examples. Profile links open datasheets; 1.6T options are marked as new generation.
50/125 µm · MM
2.000 MHz·km @ 850 nm
Typical jacket: aqua
50/125 µm · MM
4.700 MHz·km @ 850 nm
Aqua / violet
50/125 µm · MM
4.700 @850 / 2.470 @953
Wideband • lime green
~9/125 µm · SM
1310 / 1550 nm
Typical jacket: yellow
Jacket color alone does not identify the fiber class. OM5 reach benefits depend on the optic. MTP is a branded MPO implementation. Fiber characteristics ↗
| Profile / form factor | Fiber & reach | Connector | Active fibers | Optical technology | Channel IL |
|---|---|---|---|---|---|
| 1000BASE-SX ↗SFP · GLC-SX-MMD1 km is the cited Cisco laser-optimized MMF capability; do not present as universal SX standard reach. | OM3 1 km OM4 1 km OM5 1 km | LC duplex UPC | 2 | NRZ850 nm | 5 dB |
| 1000BASE-LX/LH ↗SFP · GLC-LH-SMDVendor LX/LH 10 km profile; generic IEEE LX is 5 km. Minimum cited Cisco length 2 m. | OS2 10 km | LC duplex UPC | 2 | NRZ1310 nm | 6 dB |
| 1000BASE-BX10 U/D pair ↗SFP · GLC-BX-U + GLC-BX-DOne U and one D are required. The pair uses the lower of the 5.5 dB and 6 dB directional channel limits. Minimum channel length is 2 m. | OS2 10 km | LC simplex UPC | 1 | BiDi NRZ1310 / 1490 nm complementary pair | 5.5 dB |
| 10GBASE-SR ↗SFP+ · SFP-10G-SROnly OM3 2.6 dB budget verified in cited Corning engineering note. | OM3 300 m OM4 400 m OM5 400 m | LC duplex UPC | 2 | NRZ850 nm | OM3 2.6 dB OM4 ? OM5 ? |
| 10GBASE-LR ↗SFP+ · SFP-10G-LR | OS2 10 km | LC duplex UPC | 2 | NRZ1310 nm | Unverified |
| 10GBASE-ER ↗SFP+ · SFP-10G-EREngineered link; check minimum attenuation and receiver overload, including short-link attenuator requirement. | OS2 40 km | LC duplex UPC | 2 | NRZ1550 nm | Unverified |
| 10G ZR 80 km (vendor profile) ↗SFP+ · SFP-10G-ZRVendor 80 km reach. Attenuator requirements vary with distance; verify receiver overload and measured loss. | OS2 80 km | LC duplex UPC | 2 | NRZ1550 nm | Unverified |
| 25GBASE-SR ↗SFP28 · SFP-25G-SR-S | OM3 70 m OM4 100 m OM5 100 m | LC duplex UPC | 2 | NRZ850 nm | Unverified |
| 25GBASE-LR ↗SFP28 · SFP-10/25G-LR-S | OS2 10 km | LC duplex UPC | 2 | NRZ1310 nm | Unverified |
| 25G CSR (vendor extended MMF) ↗SFP28 · SFP-10/25G-CSR-SVendor-specific extended reach depending on fiber quality, not generic 25GBASE-SR. | OM3 300 m OM4 400 m OM5 400 m | LC duplex UPC | 2 | NRZ850 nm | Unverified |
| 25GBASE-ER ↗SFP28 · SFP-25G-ER-IBeyond 30 km this is an engineered link. Check minimum attenuation and receiver overload at short reach. | OS2 40 km | LC duplex UPC | 2 | NRZ1310 nm | Unverified |
| 40GBASE-SR4 ↗QSFP+ · QSFP-40G-SR4 | OM3 100 m OM4 150 m OM5 150 m | MPO-12 UPC | 88/12 physical | 4 × 10G NRZ parallel850 nm | Unverified |
| 40GBASE-LR4 ↗QSFP+ · QSFP-40G-LR4No passive 4 × 10G breakout from the duplex LC WDM optic. | OS2 10 km | LC duplex UPC | 2 | WDM NRZ4 wavelengths near 1310 nm | Unverified |
| 50GBASE-SR ↗SFP56 · SFP-50G-SR-S | OM3 70 m OM4 100 m OM5 100 m | LC duplex UPC | 2 | PAM4850 nm | 1.9 dB |
| 50GBASE-LR ↗SFP56 · SFP-50G-LR-SUse 10 km catalog reach; beyond is an engineered vendor-specific link. | OS2 10 km | LC duplex UPC | 2 | PAM41310 nm | 8 dB |
| 100GBASE-SR4 ↗QSFP28 · QSFP-100G-SR4-SNot interchangeable with 100G SR1: optical lane modulation differs. | OM3 70 m OM4 100 m OM5 100 m | MPO-12 UPC | 88/12 physical | 4 × 25G NRZ parallel850 nm | OM3 1.8 dB OM4 1.9 dB OM5 1.9 dB |
| 100GBASE-SR1 ↗QSFP28 · QSFP-100G-SR-S | OM3 70 m OM4 100 m OM5 100 m | LC duplex UPC | 2 | 1 × 100G PAM4850 nm | Unverified |
| 100GBASE-DR ↗QSFP28 · QSFP-100G-DR-S | OS2 500 m | LC duplex UPC | 2 | 1 × 100G PAM41310 nm | 3 dB |
| 100GBASE-FR1 ↗QSFP28 · QSFP-100G-FR-SNot optically interchangeable with 100G CWDM4 despite same LC and reach. | OS2 2 km | LC duplex UPC | 2 | 1 × 100G PAM41310 nm | Unverified |
| 100G CWDM4 MSA ↗QSFP28 · QSFP-100G-CWDM4-SCannot passively break out into four ordinary 25G LC ports. | OS2 2 km | LC duplex UPC | 2 | 4 × 25G NRZ WDM1271 / 1291 / 1311 / 1331 nm | 5 dB |
| 100GBASE-LR4 ↗QSFP28 · QSFP-100G-LR4-S | OS2 10 km | LC duplex UPC | 2 | 4 × 25G NRZ LAN-WDM1295 / 1300 / 1304 / 1309 nm | 6.3 dB |
| 100GBASE-LR1 ↗QSFP28 · QSFP-100G-LR-SLR1 and LR4 are different optical interfaces. | OS2 10 km | LC duplex UPC | 2 | 1 × 100G PAM41310 nm | Unverified |
| 100G PSM4 MSA ↗QSFP28 · QSFP-100G-PSM4-S | OS2 500 m | MPO-12 APC | 88/12 physical | 4 × 25G NRZ parallel1310 nm | Unverified |
| 100G ER4-Lite ↗QSFP28 · QSFP-100G-ER4L-SEngineered link; verify loss and receiver overload. Not generic ER4 standard compliance at every distance. | OS2 40 km | LC duplex UPC | 2 | 4 × 25G NRZ LAN-WDM1295 / 1300 / 1304 / 1309 nm | Unverified |
| 100G ZR4 80 km (vendor profile) ↗QSFP28 · QSFP-100G-ZR4-S80 km depends on measured fiber/connector loss; engineered link and receiver-overload verification required. Not coherent ZR. | OS2 80 km | LC duplex UPC | 2 | 4 × 25G NRZ LAN-WDM1295 / 1300 / 1304 / 1309 nm | Unverified |
| 200GBASE-SR4 ↗QSFP56 · QSFP-200G-SR4-S | OM3 70 m OM4 100 m OM5 100 m | MPO-12 UPC | 88/12 physical | 4 × 50G PAM4 parallel850 nm | 1.9 dB |
| 200GBASE-FR4 ↗QSFP56 · QSFP-200G-FR4-S | OS2 2 km | LC duplex UPC | 2 | 4 × 50G PAM4 WDM1270 / 1290 / 1310 / 1330 nm | 4 dB |
| 400GBASE-SR8 ↗QSFP-DD · QDD-400G-SR8-S | OM3 70 m OM4 100 m OM5 100 m | MPO-16 APC | 16 | 8 × 50G PAM4 parallel850 nm | 1.9 dB |
| 400GBASE-SR4.2 ↗QSFP-DD · QDD-400G-SR4.2-BD | OM3 70 m OM4 100 m OM5 150 m | MPO-12 UPC | 88/12 physical | Bidirectional dual-wavelength 50G PAM4855 / 908 nm | 1.9 dB |
| 400GBASE-VR4 ↗QSFP112 · QSFP-400G-VR4This exact Cisco QSFP112 data sheet lists 50 m for OM3/OM4/OM5; other VR4 vendors may have 30 m OM3. | OM3 50 m OM4 50 m OM5 50 m | MPO-12 APC | 88/12 physical | 4 × 100G PAM4 parallel850 nm | 1.9 dB |
| 400GBASE-DR4 ↗QSFP112 · QSFP-400G-DR4 | OS2 500 m | MPO-12 APC | 88/12 physical | 4 × 100G PAM4 parallel1310 nm | 3 dB |
| 400GBASE-FR4 ↗QSFP112 · QSFP-400G-FR4Also available as QSFP-DD/OSFP variants; electrical form factor compatibility is independent of optical FR4 interoperability. | OS2 2 km | LC duplex UPC | 2 | 4 × 100G PAM4 WDM1270 / 1290 / 1310 / 1330 nm | 4 dB |
| 400G LR4 10 km (vendor profile) ↗QSFP-DD · QDD-400G-LR4-SIEEE 400GBASE-LR4-6 baseline reach is 6 km; this Cisco profile supports 10 km with stated loss budget. | OS2 10 km | LC duplex UPC | 2 | 4 × 100G PAM4 WDM4 wavelengths near 1310 nm | 6.3 dB |
| 800GBASE-VR8 ↗QSFP-DD800 · QDD-800G-VR8 | OM3 30 m OM4 50 m OM5 50 m | 2 × MPO-12 APC | 1616/24 physical | 8 × 100G PAM4 parallel850 nm | OM3 1.6 dB OM4 1.7 dB OM5 1.7 dB |
| 800GBASE-DR8-2 / 8 × 100G FR1 ↗QSFP-DD800 · QDD-8X100G-FR | OS2 2 km | 2 × MPO-12 APC | 1616/24 physical | 8 × 100G PAM4 parallel1310 nm | 4 dB |
| 2 × 400GBASE-FR4 (800G aggregate) ↗QSFP-DD800 · QDD-2X400G-FR4Two 400G optical interfaces in one module; do not assume a native single 800G optical interface on every host. | OS2 2 km | 2 × LC duplex UPC | 4 | 2 engines, each 4 × 100G PAM4 WDM1270 / 1290 / 1310 / 1330 nm | 4 dB |
| NVIDIA twin-port 2 × 400G DR4 ↗Twin-port OSFP · MMS4X00-NM500 m specification assumes two optical patch panels. Finned versus flat-top mechanical variant depends on host. Data sheet does not explicitly publish maximum channel IL; do not derive it by subtracting average Tx/Rx powers. | OS2 500 m | 2 × MPO-12 APC | 1616/24 physical | 2 × 4 lanes of 100G PAM41310 nm | Unverified |
| 800G SR8 · 100 m (JPC) ↗OSFP · JPC OSFP-IHS SR8This vendor profile specifies 100 m on OM4/OM5. It is distinct from 50 m VR8 and from other vendor SR8 reach limits. | OM4 100 m OM5 100 m | MPO-16 APC | 16 | 8 × 100G PAM4 parallel850 nm | Unverified |
| 800GBASE-DR8 · MPO-16 ↗OSFP · OSFP-800G-DR8P | OS2 500 m | MPO-16 APC | 16 | 8 × 100G PAM4 parallel1310 nm | 3 dB |
| 800GBASE-DR8 · 2 × MPO-12 ↗OSFP · OSFP-800G-DR8 | OS2 500 m | 2 × MPO-12 APC | 1616/24 physical | 8 × 100G PAM4 parallel1310 nm | 3 dB |
| 1.6T DR8 FRO · MPO-16 ↗OSFP · 200G/lane · OP13PI8-005D-4(R)New generation / qualifyNew-generation vendor profile. 200G optical lanes do not match 100G lanes of 800G DR8. Confirm connector polish, host, FEC and optical interoperability for the ordered SKU. | OS2 500 m | MPO-16 | 16 | 8 × 200G PAM4 · retimed1310 nm | Unverified |
| 1.6T 2 × DR4 FRO ↗OSFP · 200G/lane · OP13PI8-005D-3(R)New generation / qualifyNew-generation vendor profile. 200G optical lanes do not match 100G lanes of 800G DR8. Confirm connector polish, host, FEC and optical interoperability for the ordered SKU. | OS2 500 m | 2 × MPO-12 | 1616/24 physical | 2 × (4 × 200G PAM4) · retimed1310 nm | Unverified |
| 1.6T 2 × FR4 · 2 km ↗OSFP · 200G/lane · OP27PI8-02DNew generation / qualifyDraft 1.0 vendor datasheet. Two 800G WDM engines, 200G optical lanes. This is not the 800G aggregate 2 × 400G FR4 profile. Final specifications, connector polish and host qualification must be confirmed. | OS2 2 km | 2 × LC duplex | 4 | 2 × (4 × 200G PAM4 WDM) · retimed1271 / 1291 / 1311 / 1331 nm | Unverified |
30 October 2026
DC-01 ↔ DC-02
100G · OM4 · Patch panels + backbone
Links / route: 48 · Routes: 1 · Channel: 72 m
Profile: 100GBASE-SR4 (QSFP-100G-SR4-S)
Modules: active / stock / purchase: 96 / 10 / 106
Panels / passive U: 10 / 20U
Loss + margin / budget: 1.552 / 1.9 dB
Reach / loss check: OK / OK
PROJECT TOTAL
Optical module purchase: 106 · Panels: 10 · 20U